TEI Controls Industrial Rated Drip Irrigation Control Panel Models

Note: The below also available in .pdf format
    
  Model  DICP-02-412NC  DICP-02-412  DICP-02-622  DICP-01-826  DICP-02-1030
2 Pump 2 Pump 2 Pump 2 Pump 2 Pump
Starter & Motor Circuit Breaker Included Starter & Motor Circuit Breaker Included Starter & Motor Circuit Breaker Included Starter & Motor Circuit Breaker Included Starter & Motor Circuit Breaker Included
Starter/Breaker Type IEC Rated IEC Rated IEC Rated
Option: Nema
IEC Rated
Option: Nema
IEC Rated
Option: Nema
Pump Power Supply Single Phase
Option: 3-Phase
Single Phase
Option: 3-Phase
Single Phase
Option: 3-Phase
Single Phase
Option: 3-Phase
Single Phase
Option: 3-Phase
Single Phase IEC
Pump Rating
115Vac = 2HP
230Vac = 5HP
115Vac = 2HP
230Vac = 5HP
115Vac = 2HP
230Vac = 5HP
115Vac = 2HP
230Vac = 5HP
115Vac = 2HP
230Vac = 5HP
Three Phase IEC
Pump Rating
230Vac = 2 HP
460Vac = 20HP
230Vac = 2 HP
460Vac = 20HP
230Vac = 2 HP
460Vac = 20HP
230Vac = 2 HP
460Vac = 20HP
230Vac = 2 HP
460Vac = 20HP
Panel FRP Nema 4X
24" x 20"
FRP Nema 4X
24" x 20"
FRP Nema 4X
30" x 24"
FRP Nema 4X
36" x 30"
FRP Nema 4X
36" x 30"
Operator Interface Console (OIC) Color Touch Screen - Internal or "Through Door" Mounting Color Touch Screen - Internal or "Through Door" Mounting Color Touch Screen - Internal or "Through Door" Mounting Color Touch Screen - Internal or "Through Door" Mounting Color Touch Screen - Internal or "Through Door" Mounting
Programmable Logic Controller (PLC) 2 Individual - Autodialer Not Included 4 Individual - Autodialer Not Included 4 Individual - Autodialer Not Included 4 Individual - Autodialer Not Included 4 Individual - Autodialer Not Included
Remote Communications Option: Local DH485 Net Option: Additional RS232 Serial Port (1764-LRP) Option: Additional RS232 Serial Port (1764-LRP) Option: Additional RS232 Serial Port (1764-LRP) Option: Additional RS232 Serial Port (1764-LRP)
Type Of Remote Comm PC Screen within 8,000ft Radio or Phone Telemetry Radio or Phone Telemetry Radio or Phone Telemetry Radio or Phone Telemetry
Lightning Protection Inputs & Outputs Isolated Except Autodialer Outputs Inputs & Outputs Isolated Except Autodialer Outputs Inputs & Outputs Isolated Except Autodialer Outputs Inputs & Outputs Isolated Except Autodialer Outputs Inputs & Outputs Isolated Except Autodialer Outputs
Control Power 120Vac - UPS Recommended 120Vac - UPS Recommended 120Vac - UPS Recommended 120Vac - UPS Recommended 120Vac - UPS Recommended
Manual Operation Inputs & Outputs Are Controlled Through Hand-Off-Auto Switches Except for Autodialer Inputs & Outputs Are Controlled Through Hand-Off-Auto Switches Except for Autodialer Inputs & Outputs Are Controlled Through Hand-Off-Auto Switches Except for Autodialer Inputs & Outputs Are Controlled Through Hand-Off-Auto Switches Except for Autodialer Inputs & Outputs Are Controlled Through Hand-Off-Auto Switches Except for Autodialer
Wetwell (Storage Tank) Five Float Auto Operating System:
Low Level
Pump Off
Pump Enable
High Duty
High Level
Five Float Auto Operating System:
Low Level
Pump Off
Pump Enable
High Duty
High Level
Five Float Auto Operating System:
Low Level
Pump Off
Pump Enable
High Duty
High Level
Five Float Auto Operating System:
Low Level
Pump Off
Pump Enable
High Duty
High Level
Five Float Auto Operating System:
Low Level
Pump Off
Pump Enable
High Duty
High Level
Zones Automatic Zone Dosing Based on Time or Flow; Automatic Field Flush (7-30 Days) Automatic Zone Dosing Based on Time or Flow; Automatic Field Flush (7-30 Days) Automatic Zone Dosing Based on Time or Flow; Automatic Field Flush (7-30 Days) Automatic Zone Dosing Based on Time or Flow; Automatic Field Flush (7-30 Days) Automatic Zone Dosing Based on Time or Flow; Automatic Field Flush (7-30 Days)
Filters Automatic Filter Backwash & Air Scour Based on Back-Pressure, Dosing Time or Manual Initiation Automatic Filter Backwash & Air Scour Based on Back-Pressure, Dosing Time or Manual Initiation Automatic Filter Backwash & Air Scour Based on Back-Pressure, Dosing Time or Manual Initiation Automatic Filter Backwash & Air Scour Based on Back-Pressure, Dosing Time or Manual Initiation Automatic Filter Backwash & Air Scour Based on Back-Pressure, Dosing Time or Manual Initiation
Single Contingency Failure Protection Logic Float Failure
Pump Failure
Zone Failure
Float Failure
Pump Failure
Zone Failure
Float Failure
Pump Failure
Zone Failure
Float Failure
Pump Failure
Zone Failure
Float Failure
Pump Failure
Zone Failure


    
  Model  DICP-02-412NC  DICP-02-412  DICP-02-622  DICP-01-826  DICP-02-1030
Special Items
Cable: PLC to OIC EZ-MLOGIX-CBL EZ-MLOGIX-CBL EZ-MLOGIX-CBL EZ-MLOGIX-CBL EZ-MLOGIX-CBL
COMM Option A1:

DH485 Net to PC Up to 4000ft Away (PC & Software Not Included)
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel
1762-NET-AIC & 1761-CBL-AP00 (Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel
1762-NET-AIC & 1761-CBL-AP00 (Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel
1762-NET-AIC & 1761-CBL-AP00 (Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel
1762-NET-AIC & 1761-CBL-AP00 (Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel
COMM Option A2:

DH485 Net to PC Up to 8000ft Away (PC & Software Not Included)
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel Plus a Repeater Panel with Two 1762-NET-AICs, 1761-CBL-AM00, 24Vdc Power Supply
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel Plus a Repeater Panel with Two 1762-NET-AICs, 1761-CBL-AM00, 24Vdc Power Supply
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel Plus a Repeater Panel with Two 1762-NET-AICs, 1761-CBL-AM00, 24Vdc Power Supply
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel Plus a Repeater Panel with Two 1762-NET-AICs, 1761-CBL-AM00, 24Vdc Power Supply
1762-NET-AIC & 1761-CBL-AP00
(Added to Control Panel)
Plus a 1762-NET-AIC, 24Vdc Power Supply, 1747-CP3 Cable in a Remote Panel Plus a Repeater Panel with Two 1762-NET-AICs, 1761-CBL-AM00, 24Vdc Power Supply
COMM Option B:

Interface with RS232 Serial Modems (Serial Modem and Cable Not Included)
Not Applicable Substitute a 1764-LRP in Place of the 1764-LSP Substitute a 1764-LRP in Place of the 1764-LSP Substitute a 1764-LRP in Place of the 1764-LSP Substitute a 1764-LRP in Place of the 1764-LSP
COMM Option C:

Interface with Ethernet Modems (Ethernet Modem and Cable Not Included)
Not Applicable Substitute a 1764-LRP in Place of the 1764-LSP
Add a 1761-NET-ENI Module and 1761-CBL-AP00
Substitute a 1764-LRP in Place of the 1764-LSP
Add a 1761-NET-ENI Module and 1761-CBL-AP00
Substitute a 1764-LRP in Place of the 1764-LSP
Add a 1761-NET-ENI Module and 1761-CBL-AP00
Substitute a 1764-LRP in Place of the 1764-LSP
Add a 1761-NET-ENI Module and 1761-CBL-AP00
Three Phase IEC Replace Siemens 5SX22-xx-8 Breaker with 5SX23-xx-8 Replace Siemens 5SX22-xx-8 Breaker
with 5SX23-xx-8
Replace Siemens 5SX22-xx-8 Breaker with 5SX23-xx-8 Replace Siemens 5SX22-xx-8 Breaker with 5SX23-xx-8 Replace Siemens 5SX22-xx-8 Breaker with 5SX23-xx-8
Three Phase NEMA Not Applicable Not Applicable Replace IEC Breaker & Starter with NEMA Rated Breaker & Starter Replace IEC Breaker & Starter with NEMA Rated Breaker & Starter Replace IEC Breaker & Starter with NEMA Rated Breaker & Starter



Return to: TEI Drip Irrigation Control Panel